Ask Latest Price
Video Channel
Brand Name :MIYU
Model Number :MY-LY-H2
Certification :CE, UL, CSA
Place of Origin :China
MOQ :1 set
Payment Terms :T/T, Western Union, L/C, MoneyGram
Supply Ability :200 sets/month
Delivery Time :20-25days
Packaging Details :Standard export package
Total water flow(L/min) :IP×3:Angle±600,R:400mm,1.1L/min ; IP×4:Angle±1800,R:400mm,1.8L/min
Pressure of spray nozzle (kgf/cm2) :1P×3,Radius:400mm,open holes=16,total water flow:1:1L/min
Spray Nozzle Rotation Speed :Swing 60° from vertical for 4 seconds at one time Swing 180° from vertical for 12 seconds at one time
Power supply :C 1Ψ 110V;AC 1Ψ 220V;3Ψ380V 60/50Hz
Time Setting :1~999h999min, Adjustable
Material :SUS#304
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Touch Screen Ipx3 Ipx4 Ipx5 Ipx6 Rain/Water Spray Resistance Test Chamber

Our Design :

MIYU's modular design allows you to add on additional features, depending on the number and type of tests required. One possible choice is to integrate the spray system with a regular temperature and humidity chamber to save money and floor space, while also creating an opportunity to simulate actual operating conditions your product may experience.
Our system uses multiple control solenoids to vary the water's spray volume/pressure. A holding tank prepares the water to the desired temperature, if required. A pump ensures the water is delivered in the proper pressure range. The water is fed to a motorized manifold that rotates the spray arms. Each spray arm has an adjustable valve to allow finer control of the spray.
Testing capabilities
The specification is modeled after and doesn't differ greatly. Details about the nozzle types and the rotating nature of the spray arms and product table are also included in the requirements. Additionally, drip and car wash tests are also specified.

Heavy splash/shower:

  • S1 Spray room temperature water with 40 nozzles at 14.2 psi (1 kgf/cm2) for 30 minutes. The flow rate of the water shall be 6.5 gallons/min. (24.5 L/m).
  • S2 Spray room temperature water with 40 nozzles at 42.7 psi (3 kgf/cm2) for 60 minutes. The flow rate of the water shall be 10.3 gallons/min. (39.2 L/m).

Light spray/rain:

  • R1 Spray room temperature water with two nozzles at 4.3 psi (0.3 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.8 gallons/min. (3.2 L/m).
  • R2 Spray room temperature water with two nozzles at 1.4 psi (0.1 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.5 gallons/min. (1.9 L/m).

Examples of OEM automotive manufacturers' requirements:

  • Heat the sample to a temperature above boiling, then spray with cold water for about two minutes. Repeat cycle.
  • Heat the sample to boiling temperature, then spray with room temperature water for about fifteen minutes. Repeat cycle.
  • Simulate a car wash by using high pressure spray.

Features:

  • Rotating rain and spray nozzles designed to JIS specifications
  • Speed control for the rotating spray nozzles
  • Stationary product shelf - A rotating shelf is optional: see options
  • Water pressure regulators, gauges and flow meters
  • Special high-volume floor drain system to rapidly drain water out of the chamber
  • Interior chamber size is the smallest possible area using the JIS specified nozzles

Applicable Test Methods:

  • JSA JIS (Japanese Industrial Standard) D 0203 "Method of Moisture, Rain and Spray Test for Automobile Parts"
  • SAE (Society of Automotive Engineers) J2245 "Recommended Practice for Splash and Spray Evaluation"
  • SAE J575 "Test Methods and Equipment for Lighting Devices and Components"

"The cabinet shall be equipped with a nozzle(s) which provides a solid cone water spray of sufficient angle to completely cover the sample device. The centerline of the nozzle(s) shall be directed downward at an angle of 45 degrees to the vertical axis of a rotating test platform... The device shall be rotated about its vertical axis at a rate of 4.0 ± 0.5 rpm... The water spray test shall continue for 12 hours." ref: SAE J575.

Optional/additional test capabilities:

  • Temperature/humidity controlled rain chamber: Includes -20 to 150°C and 20 to 98%RH capabilities
  • Water recirculation: Allows re-use of the treated rain water
  • Water conditioning: Allows the water to be cooled (5 to 20°C) prior to spray
  • High pressure spray: Adds capability to meet car wash test requirement
  • Drip nozzle: Adds capability to meet drip test requirement
  • Rotating table: Rotates the sample for full exposure to spray

Tester picture:

Temperature Humidity Test Rain Water Resistance Testingfor  Ipx3 Ipx4 Ipx5 Ipx6

Technical parameters:

Model No MY-LY-H3
Working room(L) 1728 1728
Inner chamber size(mm)W*H*D 1200*1200*1200 1200*1200*1200
Exterior chamber size(mm)W*H*D 1750*1850*1300 1750*1850*1300
Packaging volume(CBM) 5.5 5.5
G.W.(KGs) 600 600
Water Temperature Normal Normal
Spray Type Total water
flow(L/min)
R1 1.8 IP×1 With in 1~1.5mm/min(In drip box)
R2 3.2 IP×2 With in 3~3.5mm/min(In drip box)
S1 24.5 IP×3 Angle±600,R:400mm,1.1L/min
S2 39.2 IP×4 Angle±1800,R:400mm,1.8L/min
Pressure of
spray nozzle
(kgf/cm2)
R1 0.1 1.Flow rate of the water=0.07L/min
2.1P×3,Radius:400mm,open holes=16,total water flow:1:1L/min.
3.1P×4,Radius:400mm,open holes=25,total water flow:1:8L/min.
*Radius: 200mm,R400mm(For 1P×3,1P×4 only)
R2 0.3
S1 1
S2 3
Test Specimen Frame(RPM) 17RPM 1RPM
Spray Nozzle Rotation Speed 23RPM Swing 60° from vertical for 4 seconds at one time
Swing 180° from vertical for 12 seconds at one time
Material Inner chamber material SUS#304
Exterior chamber material
Other Components Chamber lamp.Wiper
casters with Adjusters
Chamber lamp.Wiper
casters with Adjusters
Power supply C 1Ψ 110V;AC 1Ψ 220V;3Ψ380V 60/50Hz
Customized service Welcome to Non-standard,Specail requirements,OEM/ODM orders.
The technical information will be subjected to change without notice

Temperature Humidity Test Rain Water Resistance Testingfor  Ipx3 Ipx4 Ipx5 Ipx6

Temperature Humidity Test Rain Water Resistance Testingfor  Ipx3 Ipx4 Ipx5 Ipx6

Temperature Humidity Test Rain Water Resistance Testingfor  Ipx3 Ipx4 Ipx5 Ipx6

Temperature Humidity Test Rain Water Resistance Testingfor  Ipx3 Ipx4 Ipx5 Ipx6

Temperature Humidity Test Rain Water Resistance Testingfor  Ipx3 Ipx4 Ipx5 Ipx6

Temperature Humidity Test Rain Water Resistance Testingfor  Ipx3 Ipx4 Ipx5 Ipx6

FAQ

1. Do you offer after-sales service? How can I ask for that? And how about the warranty?

Every machine from our factory has a 1 year warranty after shipment. Generally, we offer 1 year for the FREE maintenance for our customers. If your machine doesn’t work, you can send E-mail to us and we will try our best to find the problem by email or skype video chat if neccesary. After confirmation of the problem, we can send you new spare parts or provide on-site repair.

2. What’s the delivery term?

Normally, the delivery time is 10-25 working days after deposit receipt. If you are in urgent need, we can consider making a special arrangement for you.

3. Do you accept customization service? Can I have my logo on the machine?
Yes, of course. We can not only offer standard machines, but also customized machines according to your requirements. And we can also put your logo on the machine.

4. How to install and use the product?
We will send you operating instructions, most of our machine is shipped with a whole part, which means it is already installed, all you need to do is to connect the power cable and start to use. And if possible, we can also install your machine at your location.

Inquiry Cart 0